    The ECO2 storage cabinet is a more simplified and environmentally friendly product without sacrificing performance, functionality and quality. In response to a demanding market, our R+D+i department has developed this new model based on two fundamental premises: Economy and Ecology, hence its name. All of this while maintaining the technology used in our ductless fume hoods, which allows the vapours generated inside to be adsorbed and does not require a connection to the outside. In this way, it allows liquid or solid reagents to be stored inside and prevents both dust and toxic, inflammable or corrosive vapours from accumulating inside or being expelled into the working room.
     
    ico-cruma-calidad-eco-150x150
    Certified

    Manufactured in Barcelona and certified by an external laboratory following international standards, applying the criteria of ISO 9001:2015.

    ico-cruma-a-medida-eco-150x150
    Mobility and Flexibility

    Due to its dimensions and reduced weight, as well as the absence of works to install a duct system outside, the possibilities of location and replacement are simpler. Moreover, as it is a dismountable product, it can be stored and placed in any laboratory without any problem (narrow passages, narrow or difficult to access stairs, etc.).

    ico-cruma-seguridad-eco-150x150
    Protection

    Thanks to its filtration system, the aspirated air is recirculated back into the room free of contaminants, thus allowing a constant renewal of the room air. Toxic vapors and contaminating particles are captured inside the filter, where they are neutralized.

    ico-cruma-proteccion-eco-150x150
    Green and Sustainable

    In addition, not consuming the laboratory’s air conditioning, it substantially reduces energy costs while providing point-of-use protection without releasing hazardous pollutants into the atmosphere.

    Advantages


    Yes, they all fit and are standard.

    Mechanical anemometer
    Illumination
    Exhausted air sampling probe
    Lock
    Inert absorbent mat
    G4 Pre-filter
    Warranty: 2 years

     

    Cruma-Armario-Almacenamiento-Ventilado-Eco-2-full

    Possible Applications

    Storage of chemicals under the criteria of incompatibilities. Filters available:
    Available Filters:

    ▼ Type A: adsorption of vapours and organic solvents (ketones, ethers, alcohols
    and cyclics, etc.). Activated carbon without impregnation.

    ▼ Type BE: inorganic gases such as Cl2, HCl, HNO3, etc. and volatile sulphur
    compounds (H2S, H2SO4 and SOx, etc.). Activated carbon impregnated with
    metal compounds and neutralising salts.

    ▼ Type F: specific to formaldehyde and derivatives. Impregnated with Cu.

    ▼ Type K: Suitable for ammoniacal vapours (NH3) and amines.

    ▼ Type D: HEPA H-14 filter, suitable for the filtration of dusts.

    The Cruma 2010 Eco2 vented storage cupboard are designed to ensure that no handling operations are necessary once these have been received: all you have to do is take them out of their fantastic packaging, place them in the desired spot, plug them into the mains and get to work. As simple as plug in and play.

    armario-ventilado-sistema-filtracion-gama-classic

    Our vented storage cupboard use the new filtration system, developed and patented by Cruma (Invention Patent), which protects the operator by retaining the contaminating gas and fumes generated inside from stored botles, constantly renewing the air inside the laboratory and avoiding leaks that may contaminate the environment.

     
    Models and Technical Specifications

    A variety of sizes to suit all needs

     
      Cruma-Armario-Almacenamiento-Ventilado-Eco-2-full  
    Model 2010 Eco2  
    Internal Sizes (Width/Depth/High) 760 x 468 x 1393  
    External Sizes (Width/Depth/High) 800 x 500 x 1835  
    Filtering columns 1  
    Filter number 1 a 2  
    Fans 1  
    Average volume of treated air/hour 160 m3/h  
    Average face velocity 0.50 m/s  
    Internal volume of the cabinet 0.567m3  
    Renewals inside the cabinet/min. 4.6 ren./s  
    Total electrical power consumption 91 W  
    Voltage-Frequency 110-220 V / 50-60 Hz  
    LED light intensity 800Lux / LED 16 W  
    Shelves 4  
    Noise level 48 dB  
    Weight 150 Kg  

     

    Serial Equipment
    Full Equip cabinets
     
    Equipment Description
    Electronic circuit with large format LCD screen Security levels: level 1 for users and level 2 for maintenance users
    Anemometer device Electronic sensor monitoring continuously air face velocity
    Electronic control device for filters replacement The filters incorporate a microchip with miniUSB connection that identifies the type of filter installed, the expiry date and the serial no.
    Illumination 96 LED Tube high light intensity and low power consumption – 16 Watts / 700 Lux
    Sampling system to analize the filtered air at the exhaust To detect the level of filter saturation
    60 hours alarm Countdown timer according to French NF X 15-211:2009
    Electronic cronometre with audible alarm To program the work inside the fume hood
    Clock and calendar Display of date and time
    G4 Prefilter G4 class pre-filtering blanket of synthetic biofibres  (according to EN-779) for the retention of atmospheric dust
    Chemical Listing Guide of retained products by type of filter
    Warranty 2 years

     

    Optional Equipment
    Details that matter
     
    Equipment Description
    Voltage / Frequency 125 V / 50 Hz
    Filter test kit Dräger pump with reactive colorimetric tubes (pack 10u)

     

    Cruma Filters
    A wide range to ensure the air remains clean and health is unaffected
    filter-2-cruma-1
     
    Filter type Description
    Type A For organic vapors such as ketones, ethers, alcohols, xylenes… Eventually it can be used for inorganic acids, but only if used in small quantities because this activated carbon is not impregnated and the excess of acid vapors could saturate it quickly.
    Type BE For inorganic acid vapors as H2SO4, HCl, HNO3, and volatile sulfur compounds such as H2S, SO3, … It can be used with organic vapors because the activated carbon incorporates impregnation of metal compounds and neutralizing salts. It is also suitable to filter organic and inorganic compounds when they are in similar proportions.
    Type F For formaldehyde vapors and derivatives; also good for other organic compounds. Carbon impregnated with Cu leads, so that it should never be used with inorganic acid vapors.

     

    Incompatibilities In The Storage Of Chemical Products Separate Or Joint Storage 

      Explos. Combu. Inflam. Toxic Corrosive Harmful
    Explosives YES NO NO NO NO NO
    Comburents NO YES NO NO NO (2)
    Inflammable NO NO YES NO (1) YES
    Toxic NO NO (1) YES YES YES
    Corrosive NO NO (1) YES YES YES
    Harmful NO (2) YES YES YES YES 

     

    (1) They may be stored together if corrosive products are not packed in fragile containers.
    (2) They may be stored together if certain measures of prevention are taken. These are general criteria. For any other type of classification of danger levels, the possible storage incompatibilities must be more fully examined.

    • Products that react with water must not  be stored in the same area as other inflammable
      or combustible liquids.
    • Inflammable or combustible liquids must  not be stored in conventional refrigerators.

    Modular filtration column
    for gases and particles  (according to NFX 15-211:2009) 

    CLASS 2
    Type G Handling of liquid compounds/products columnas-filtrantes-tipo-g

     

    Type GS Handling of liquid and particles compounds/products columnas-filtrantes-tipo-gs

     

     

    ventilador Fan   -   molecula-filter Molecular Filter   -   particle-filter HEPA-H14 Filter

     

    Incompatibilities
    Separation methods. Segregation criteria.

    Number Chemical Group Do Not Store With Chemical Number Groups With The Indicate Numbers
    1 Inorganic acids 2-8, 10, 11, 13, 14, 16-19, 21, 22, 23
    2 Organic acids 1, 3, 4, 7, 14, 16, 17-19, 22
    3 Caustic products 1, 2, 6, 7, 8, 13-18, 20, 22, 23
    4 Amines and alkanolamines 1, 2, 5, 7, 8, 13-18, 23
    5 Halogenated compounds 1, 3, 4, 11, 14, 17
    6 Alcohols, glycols, glycol-ethers 1, 7, 14, 16, 20, 23
    7 Aldehydes 1-4, 6, 8, 15-17, 19, 20, 23
    8 Ketones 1, 3, 4, 7, 19, 20
    9 Saturated hydrocarbons 20
    10 Aromatic hydrocarbons 1, 20
    11 Olefins 1, 5, 10
    12 Petroleum oils 20
    13 Esters 1, 3, 4, 19, 20
    14 Monomers, polymerisable esters 1-6, 15, 16, 19-21, 23
    15 Phenols 3, 4, 7, 14, 16, 19, 20
    16 Alkylene oxides 1-4, 6, 7, 14, 15, 17-19, 23
    17 Cyanohydrins 1-5, 7, 16, 19, 23
    18 Nitryls 1-4, 16, 23
    19 Ammonia 1-2, 7, 8, 13-17, 20, 23
    20 Halogens 3, 6-15, 19, 21, 22
    21 Ethers 1, 14, 20
    22 Elemental phosphorous 1-3, 20
    23 Acid anhydrides 1, 3, 4, 6, 7, 14, 16-19

     