Vented Storage Cupboard Eco2
Cruma 2O1O Eco2
The ECO2 storage cabinet is a more simplified and environmentally friendly product without sacrificing performance, functionality and quality. In response to a demanding market, our R+D+i department has developed this new model based on two fundamental premises: Economy and Ecology, hence its name. All of this while maintaining the technology used in our ductless fume hoods, which allows the vapours generated inside to be adsorbed and does not require a connection to the outside. In this way, it allows liquid or solid reagents to be stored inside and prevents both dust and toxic, inflammable or corrosive vapours from accumulating inside or being expelled into the working room.
Certified
Manufactured in Barcelona and certified by an external laboratory following international standards, applying the criteria of ISO 9001:2015.
Mobility and Flexibility
Due to its dimensions and reduced weight, as well as the absence of works to install a duct system outside, the possibilities of location and replacement are simpler. Moreover, as it is a dismountable product, it can be stored and placed in any laboratory without any problem (narrow passages, narrow or difficult to access stairs, etc.).
Protection
Thanks to its filtration system, the aspirated air is recirculated back into the room free of contaminants, thus allowing a constant renewal of the room air. Toxic vapors and contaminating particles are captured inside the filter, where they are neutralized.
Green and Sustainable
In addition, not consuming the laboratory’s air conditioning, it substantially reduces energy costs while providing point-of-use protection without releasing hazardous pollutants into the atmosphere.
Advantages
Yes, they all fit and are standard.
▼ Mechanical anemometer
▼ Illumination
▼ Exhausted air sampling probe
▼ Lock
▼ Inert absorbent mat
▼ G4 Pre-filter
▼ Warranty: 2 years
Possible Applications
Storage of chemicals under the criteria of incompatibilities. Filters available:
Available Filters:
▼ Type A: adsorption of vapours and organic solvents (ketones, ethers, alcohols
and cyclics, etc.). Activated carbon without impregnation.
▼ Type BE: inorganic gases such as Cl2, HCl, HNO3, etc. and volatile sulphur
compounds (H2S, H2SO4 and SOx, etc.). Activated carbon impregnated with
metal compounds and neutralising salts.
▼ Type F: specific to formaldehyde and derivatives. Impregnated with Cu.
▼ Type K: Suitable for ammoniacal vapours (NH3) and amines.
▼ Type D: HEPA H-14 filter, suitable for the filtration of dusts.
The Cruma 2010 Eco2 vented storage cupboard are designed to ensure that no handling operations are necessary once these have been received: all you have to do is take them out of their fantastic packaging, place them in the desired spot, plug them into the mains and get to work. As simple as plug in and play.
Our vented storage cupboard use the new filtration system, developed and patented by Cruma (Invention Patent), which protects the operator by retaining the contaminating gas and fumes generated inside from stored botles, constantly renewing the air inside the laboratory and avoiding leaks that may contaminate the environment.
A variety of sizes to suit all needs
Model | 2010 Eco2 | |
Internal Sizes (Width/Depth/High) | 760 x 468 x 1393 | |
External Sizes (Width/Depth/High) | 800 x 500 x 1835 | |
Filtering columns | 1 | |
Filter number | 1 a 2 | |
Fans | 1 | |
Average volume of treated air/hour | 160 m3/h | |
Average face velocity | 0.50 m/s | |
Internal volume of the cabinet | 0.567m3 | |
Renewals inside the cabinet/min. | 4.6 ren./s | |
Total electrical power consumption | 91 W | |
Voltage-Frequency | 110-220 V / 50-60 Hz | |
LED light intensity | 800Lux / LED 16 W | |
Shelves | 4 | |
Noise level | 48 dB | |
Weight | 150 Kg |
Equipment | Description |
---|---|
Electronic circuit with large format LCD screen | Security levels: level 1 for users and level 2 for maintenance users |
Anemometer device | Electronic sensor monitoring continuously air face velocity |
Electronic control device for filters replacement | The filters incorporate a microchip with miniUSB connection that identifies the type of filter installed, the expiry date and the serial no. |
Illumination | 96 LED Tube high light intensity and low power consumption – 16 Watts / 700 Lux |
Sampling system to analize the filtered air at the exhaust | To detect the level of filter saturation |
60 hours alarm | Countdown timer according to French NF X 15-211:2009 |
Electronic cronometre with audible alarm | To program the work inside the fume hood |
Clock and calendar | Display of date and time |
G4 Prefilter | G4 class pre-filtering blanket of synthetic biofibres (according to EN-779) for the retention of atmospheric dust |
Chemical Listing | Guide of retained products by type of filter |
Warranty | 2 years |
Equipment | Description |
---|---|
Voltage / Frequency | 125 V / 50 Hz |
Filter test kit | Dräger pump with reactive colorimetric tubes (pack 10u) |
Filter type | Description |
---|---|
Type A | For organic vapors such as ketones, ethers, alcohols, xylenes… Eventually it can be used for inorganic acids, but only if used in small quantities because this activated carbon is not impregnated and the excess of acid vapors could saturate it quickly. |
Type BE | For inorganic acid vapors as H2SO4, HCl, HNO3, and volatile sulfur compounds such as H2S, SO3, … It can be used with organic vapors because the activated carbon incorporates impregnation of metal compounds and neutralizing salts. It is also suitable to filter organic and inorganic compounds when they are in similar proportions. |
Type F | For formaldehyde vapors and derivatives; also good for other organic compounds. Carbon impregnated with Cu leads, so that it should never be used with inorganic acid vapors. |
Incompatibilities In The Storage Of Chemical Products Separate Or Joint Storage
Explos. | Combu. | Inflam. | Toxic | Corrosive | Harmful | |
---|---|---|---|---|---|---|
Explosives | YES | NO | NO | NO | NO | NO |
Comburents | NO | YES | NO | NO | NO | (2) |
Inflammable | NO | NO | YES | NO | (1) | YES |
Toxic | NO | NO | (1) | YES | YES | YES |
Corrosive | NO | NO | (1) | YES | YES | YES |
Harmful | NO | (2) | YES | YES | YES | YES |
(1) They may be stored together if corrosive products are not packed in fragile containers.
(2) They may be stored together if certain measures of prevention are taken. These are general criteria. For any other type of classification of danger levels, the possible storage incompatibilities must be more fully examined.
- Products that react with water must not be stored in the same area as other inflammable
or combustible liquids. - Inflammable or combustible liquids must not be stored in conventional refrigerators.
Modular filtration column
for gases and particles (according to NFX 15-211:2009)
CLASS 2 | |
---|---|
Type G Handling of liquid compounds/products |
|
Type GS Handling of liquid and particles compounds/products |
|
Fan - Molecular Filter - HEPA-H14 Filter
Incompatibilities
Separation methods. Segregation criteria.
Number | Chemical Group | Do Not Store With Chemical Number Groups With The Indicate Numbers |
---|---|---|
1 | Inorganic acids | 2-8, 10, 11, 13, 14, 16-19, 21, 22, 23 |
2 | Organic acids | 1, 3, 4, 7, 14, 16, 17-19, 22 |
3 | Caustic products | 1, 2, 6, 7, 8, 13-18, 20, 22, 23 |
4 | Amines and alkanolamines | 1, 2, 5, 7, 8, 13-18, 23 |
5 | Halogenated compounds | 1, 3, 4, 11, 14, 17 |
6 | Alcohols, glycols, glycol-ethers | 1, 7, 14, 16, 20, 23 |
7 | Aldehydes | 1-4, 6, 8, 15-17, 19, 20, 23 |
8 | Ketones | 1, 3, 4, 7, 19, 20 |
9 | Saturated hydrocarbons | 20 |
10 | Aromatic hydrocarbons | 1, 20 |
11 | Olefins | 1, 5, 10 |
12 | Petroleum oils | 20 |
13 | Esters | 1, 3, 4, 19, 20 |
14 | Monomers, polymerisable esters | 1-6, 15, 16, 19-21, 23 |
15 | Phenols | 3, 4, 7, 14, 16, 19, 20 |
16 | Alkylene oxides | 1-4, 6, 7, 14, 15, 17-19, 23 |
17 | Cyanohydrins | 1-5, 7, 16, 19, 23 |
18 | Nitryls | 1-4, 16, 23 |
19 | Ammonia | 1-2, 7, 8, 13-17, 20, 23 |
20 | Halogens | 3, 6-15, 19, 21, 22 |
21 | Ethers | 1, 14, 20 |
22 | Elemental phosphorous | 1-3, 20 |
23 | Acid anhydrides | 1, 3, 4, 6, 7, 14, 16-19 |