Skip to content

Vented Storage Cupboard Eco2

Cruma 2O1O Eco2

Cruma-Armario-Almacenamiento-Ventilado-Eco-2-1
The ECO2 storage cabinet is a more simplified and environmentally friendly product without sacrificing performance, functionality and quality. In response to a demanding market, our R+D+i department has developed this new model based on two fundamental premises: Economy and Ecology, hence its name. All of this while maintaining the technology used in our ductless fume hoods, which allows the vapours generated inside to be adsorbed and does not require a connection to the outside. In this way, it allows liquid or solid reagents to be stored inside and prevents both dust and toxic, inflammable or corrosive vapours from accumulating inside or being expelled into the working room.
 
ico-cruma-calidad-eco-150x150
Certified

Manufactured in Barcelona and certified by an external laboratory following international standards, applying the criteria of ISO 9001:2015.

ico-cruma-a-medida-eco-150x150
Mobility and Flexibility

Due to its dimensions and reduced weight, as well as the absence of works to install a duct system outside, the possibilities of location and replacement are simpler. Moreover, as it is a dismountable product, it can be stored and placed in any laboratory without any problem (narrow passages, narrow or difficult to access stairs, etc.).

ico-cruma-seguridad-eco-150x150
Protection

Thanks to its filtration system, the aspirated air is recirculated back into the room free of contaminants, thus allowing a constant renewal of the room air. Toxic vapors and contaminating particles are captured inside the filter, where they are neutralized.

ico-cruma-proteccion-eco-150x150
Green and Sustainable

In addition, not consuming the laboratory’s air conditioning, it substantially reduces energy costs while providing point-of-use protection without releasing hazardous pollutants into the atmosphere.

Advantages


Yes, they all fit and are standard.

Mechanical anemometer
Illumination
Exhausted air sampling probe
Lock
Inert absorbent mat
G4 Pre-filter
Warranty: 2 years

 

Cruma-Armario-Almacenamiento-Ventilado-Eco-2-full

Possible Applications

Storage of chemicals under the criteria of incompatibilities. Filters available:
Available Filters:

▼ Type A: adsorption of vapours and organic solvents (ketones, ethers, alcohols
and cyclics, etc.). Activated carbon without impregnation.

▼ Type BE: inorganic gases such as Cl2, HCl, HNO3, etc. and volatile sulphur
compounds (H2S, H2SO4 and SOx, etc.). Activated carbon impregnated with
metal compounds and neutralising salts.

▼ Type F: specific to formaldehyde and derivatives. Impregnated with Cu.

▼ Type K: Suitable for ammoniacal vapours (NH3) and amines.

▼ Type D: HEPA H-14 filter, suitable for the filtration of dusts.

The Cruma 2010 Eco2 vented storage cupboard are designed to ensure that no handling operations are necessary once these have been received: all you have to do is take them out of their fantastic packaging, place them in the desired spot, plug them into the mains and get to work. As simple as plug in and play.

armario-ventilado-sistema-filtracion-gama-classic

Our vented storage cupboard use the new filtration system, developed and patented by Cruma (Invention Patent), which protects the operator by retaining the contaminating gas and fumes generated inside from stored botles, constantly renewing the air inside the laboratory and avoiding leaks that may contaminate the environment.

 
Models and Technical Specifications

A variety of sizes to suit all needs

 
  Cruma-Armario-Almacenamiento-Ventilado-Eco-2-full  
Model 2010 Eco2  
Internal Sizes (Width/Depth/High) 760 x 468 x 1393  
External Sizes (Width/Depth/High) 800 x 500 x 1835  
Filtering columns 1  
Filter number 1 a 2  
Fans 1  
Average volume of treated air/hour 160 m3/h  
Average face velocity 0.50 m/s  
Internal volume of the cabinet 0.567m3  
Renewals inside the cabinet/min. 4.6 ren./s  
Total electrical power consumption 91 W  
Voltage-Frequency 110-220 V / 50-60 Hz  
LED light intensity 800Lux / LED 16 W  
Shelves 4  
Noise level 48 dB  
Weight 150 Kg  

 

Serial Equipment
Full Equip cabinets
 
Equipment Description
Electronic circuit with large format LCD screen Security levels: level 1 for users and level 2 for maintenance users
Anemometer device Electronic sensor monitoring continuously air face velocity
Electronic control device for filters replacement The filters incorporate a microchip with miniUSB connection that identifies the type of filter installed, the expiry date and the serial no.
Illumination 96 LED Tube high light intensity and low power consumption – 16 Watts / 700 Lux
Sampling system to analize the filtered air at the exhaust To detect the level of filter saturation
60 hours alarm Countdown timer according to French NF X 15-211:2009
Electronic cronometre with audible alarm To program the work inside the fume hood
Clock and calendar Display of date and time
G4 Prefilter G4 class pre-filtering blanket of synthetic biofibres  (according to EN-779) for the retention of atmospheric dust
Chemical Listing Guide of retained products by type of filter
Warranty 2 years

 

Optional Equipment
Details that matter
 
Equipment Description
Voltage / Frequency 125 V / 50 Hz
Filter test kit Dräger pump with reactive colorimetric tubes (pack 10u)

 

Cruma Filters
A wide range to ensure the air remains clean and health is unaffected
filter-2-cruma-1
 
Filter type Description
Type A For organic vapors such as ketones, ethers, alcohols, xylenes… Eventually it can be used for inorganic acids, but only if used in small quantities because this activated carbon is not impregnated and the excess of acid vapors could saturate it quickly.
Type BE For inorganic acid vapors as H2SO4, HCl, HNO3, and volatile sulfur compounds such as H2S, SO3, … It can be used with organic vapors because the activated carbon incorporates impregnation of metal compounds and neutralizing salts. It is also suitable to filter organic and inorganic compounds when they are in similar proportions.
Type F For formaldehyde vapors and derivatives; also good for other organic compounds. Carbon impregnated with Cu leads, so that it should never be used with inorganic acid vapors.

 

Incompatibilities In The Storage Of Chemical Products Separate Or Joint Storage 

  Explos. Combu. Inflam. Toxic Corrosive Harmful
Explosives YES NO NO NO NO NO
Comburents NO YES NO NO NO (2)
Inflammable NO NO YES NO (1) YES
Toxic NO NO (1) YES YES YES
Corrosive NO NO (1) YES YES YES
Harmful NO (2) YES YES YES YES 

 

(1) They may be stored together if corrosive products are not packed in fragile containers.
(2) They may be stored together if certain measures of prevention are taken. These are general criteria. For any other type of classification of danger levels, the possible storage incompatibilities must be more fully examined.

  • Products that react with water must not  be stored in the same area as other inflammable
    or combustible liquids.
  • Inflammable or combustible liquids must  not be stored in conventional refrigerators.

Modular filtration column
for gases and particles  (according to NFX 15-211:2009) 

CLASS 2
Type G Handling of liquid compounds/products columnas-filtrantes-tipo-g

 

Type GS Handling of liquid and particles compounds/products columnas-filtrantes-tipo-gs

 

 

ventilador Fan   -   molecula-filter Molecular Filter   -   particle-filter HEPA-H14 Filter

 

Incompatibilities
Separation methods. Segregation criteria.

Number Chemical Group Do Not Store With Chemical Number Groups With The Indicate Numbers
1 Inorganic acids 2-8, 10, 11, 13, 14, 16-19, 21, 22, 23
2 Organic acids 1, 3, 4, 7, 14, 16, 17-19, 22
3 Caustic products 1, 2, 6, 7, 8, 13-18, 20, 22, 23
4 Amines and alkanolamines 1, 2, 5, 7, 8, 13-18, 23
5 Halogenated compounds 1, 3, 4, 11, 14, 17
6 Alcohols, glycols, glycol-ethers 1, 7, 14, 16, 20, 23
7 Aldehydes 1-4, 6, 8, 15-17, 19, 20, 23
8 Ketones 1, 3, 4, 7, 19, 20
9 Saturated hydrocarbons 20
10 Aromatic hydrocarbons 1, 20
11 Olefins 1, 5, 10
12 Petroleum oils 20
13 Esters 1, 3, 4, 19, 20
14 Monomers, polymerisable esters 1-6, 15, 16, 19-21, 23
15 Phenols 3, 4, 7, 14, 16, 19, 20
16 Alkylene oxides 1-4, 6, 7, 14, 15, 17-19, 23
17 Cyanohydrins 1-5, 7, 16, 19, 23
18 Nitryls 1-4, 16, 23
19 Ammonia 1-2, 7, 8, 13-17, 20, 23
20 Halogens 3, 6-15, 19, 21, 22
21 Ethers 1, 14, 20
22 Elemental phosphorous 1-3, 20
23 Acid anhydrides 1, 3, 4, 6, 7, 14, 16-19