Skip to content
Logo Glove Box Australia

    Vertical Laminar Flow Cabinets

    670FL, 870FL, FL-1, FL-2

    fl-cruma-fume-hood-hd-5
    To ensure the reliability of the tests, it is essential that the work carried out inside the cabinet does not become contaminated. To create an environment that is safe and particle-free, the vertical laminar flow cabinets we manufacture produce a stream of Class ISO 5 sterile air. This air passes through a H14 HEPA filter (manufactured pursuant to Standard EN-1822) at a constant speed, travelling downward through the cabinet in a vertical laminar flow and producing sterile air, protecting the product from external contamination and possible cross-contamination between samples.

    The cabinets that are equipped with our filtration system, which has a minimum efficiency rate of 99.995% for 0.3 µm particles in the upper part of the filter and an extraction rate of 100% as regards the air flow to the outside.
    ico-cruma-proteccion
    Sample Protection. Total Sterility

    Cruma's vertical laminar flow cabinets guarantee a laminar stream of air with class ISO 5 air purity pursuant to Standard EN14644-1 thanks to our intelligent H14 HEPA filters, providing a minimum efficiency rate of 99.995% for 0.3 µm particles.

    ico-cruma-flexibles
    Flexible
     
    These can be used in areas where it is difficult to extract contaminated air, such as the lower floors of buildings, and they can be placed in different locations, which it means that they can be easily relocated if needed.
    ico-cruma-ahorro
    Economic Savings and Easy to Set-Up
     
    No expensive works are necessary to install conduits to extract the gas to the outside which means there are no additional costs and no need to interrupt a laboratory working at full capacity.
    ico-cruma-ahorro-energetico
    Energy Savings
     
    Unlike other brands, our cabinets do not consume the air conditioning of the laboratory, which substantially reduces energy costs: the filtered air is not expelled to the outside, but recirculated back into the laboratory free of contaminating particles.

    Advantages

     

    Manufacture: the external surfaces are made of cold-rolled steel, coated with white epoxy, enamelled in ovens at 200ºC and resistant to the chemical compounds used for sterilization.

    Work Surface: the surface of the work chamber is made of white secured glass, highly resistant to impacts and chemical attacks.

    Absolute H14 HEPA Filter with a flow equalizer and an efficiency rate of over 99.995% for particles measuring 0.3 microns. Standards MIL-F51068C and BS 3298.

    Fan motors: double aspiration centrifugal fans, capable of providing a laminar flow in the work space, above all as regards dealing with filter saturation to a maximum value of 400 Pascal.

    Control Panel: Soft-touch keyboard with a switch for the LED lamps, UV ultraviolet lights, a maintenance system to control the airspeed through the HEPA filter that is electronically self-regulated and a control key to reduce speed in ECO mode.

    Lighting: LED lamps located in the centre with a prismatic diffusing screen to improve the distribution of light on the work surface.

    870fl-flujo-laminar-cruma

    Possible Applications

     

    ▼ Laboratory food industries in general
    ▼ Transfer of drugs in the pharmacy department
    ▼ Hematology and clinical analysis
    ▼ Filled with antibiotics and injectable drugs (except cytostatic) microscopic analysis
    ▼ Tissue culture bags reconstitution of parenteral methods of assisted fertilization techniques
    ▼ Micropropagation, Plant cell cultures, Water quality control, manufacturing of electronic devices…


     

    arrows_stretch_diagonal1

    127x34mm LCD Display

    Type of filter installed
    Working hours
    Wxpiration date and next revision date
    Countdown timer
    Clock and Calendar

    basic_star

    New features and components

    Initial cycle flow adequacy and final purge cycle
    Fault LED
    Control of air flow through Microprocessor
    HEPA filters with electronic chip
    LED illumination

    music_bell

    New alarms and scheduled warnings

    Next validation warning
    Few hours of filter life warning
    Countdown timer warning
    Expired filter alarm by hours & by date
    Equipment without filter alarm

    In the vertical laminar flow cabinets the stream of air passes through the H14 HEPA filter (manufactured pursuant to EN-1822) at a constant speed, travelling vertically through the cabinet in a laminar flow and producing a Class ISO 5 sterile environment (former American Federal Standard 209E) and protecting the product from external contamination and possible cross-contamination between samples.

    sistema-filtracion-gama-fl-vertical

    Single-stage filtration system with a minimum efficiency rate of 99.995% for particles of 0.3 µm in the upper part with an extraction rate of 100% as regards the air flow to the outside. Total protection for the sample.

     
    Models and Technical Specifications

    All sizes for all needs.

     
      670FL-Cruma-Fume-Hood-thumb

     

    870FL-Cruma-Fume-Hood-thumb

     

    FL-1-Cruma-Fume-Hood-thumb

     

    FL-2-Cruma-Fume-Hood-thumb

     

    Model 670FL 870FL FL-1 FL-2
    Internal Sizes (Width/Depth/High) 575x560x630 775x560x740 710x556x610 1110x556x610
    Medidas externas (Width/Depth/High) 600x600x930 800x600x1125 800x600x1137 1200x600x1137
    Filter columns - - - -
    Filter number 1 1 1 1
    Fans 1 1 1 1
    Average volume of treated air/hour - - - -
    Average face velocity 0.40 m/s 0.40 m/s 0.40 m/s 0.40 m/s
    Internal volume of the cabinet 0.181m3 0.287m3 0.236m3 0.376m3
    Renewals inside the cabinet/min. - - - -
    Total electrical power consumption 102 W 226 W 226 W 226 W
    Voltage-Frequency 110-220 V / 50-60 Hz 110-220 V / 50-60 Hz 110-220 V / 50-60 Hz 110-220 V / 50-60 Hz
    LED light intensity 900 Lux 16 W 900 Lux 16 W 900 Lux 16 W 900 Lux 16 W
    UV Lamp 1x15W 1x15W 1x15W 1x15W
    Sound level 48 dB 50 dB 50 dB 50 dB
    Weight 65 Kg 92 Kg 112 Kg 142 Kg
    Packaging volume 0.28 m3 0.42 m3 0.74 m3 0.95 m3

     

    Serial Equipment
    Full Equip cabinets
     
    Equipment Description
    Electronic circuit with large format LCD display Security levels: level 1 for users and level 2 for maintenance users
    Filters controlled by microprocessor The filters are provided with a  microchip with mini USB connection identifying the type of filter installed, the expiry date and the serial number
    Illumination 96 LED high light intensity and low consumption 16 Watts / 900 Lux
    Digital timer with audible warning Hourmeter for the control and warning of the work in the cabinet
    Clock and Calendar Display of date and time
    Work surface 1 Liquid retention tray (2-10 liters) with working surface in white tempered glass
    HEPA H-14 filter Manufactured according to EN 1822 with a minimum efficiency of 99.998% for particles of 0.3 microns
    G4 Prefilter Pre-filtering class G4 biofibre synthetic blanket
    Warranty 7 years

     

    Optional Equipment
    Details that matter
     
    Equipment Description
    Movilair Stand with wheels and internal tray in Epoxy coated steel
    Tubular steel stand Support stand in Epoxy coated steel
    Working surface 2 Spill retention tray (2-10 liters) with working surface in phenolic resin
    Working surface 3 Spill retention tray (2-10 liters) with working surface in inox steel
    Transparent rear back pannel Transparent polymethylmethacrylate rear pannel 8 mm thick (light transmission of 93%). Ideal for teaching sessions.
    Voltage / Frequency 125 V / 50 Hz
    Filter test kit Dräger pump with reactive colorimetric tubes (pack 10u)
    Cruma Filters

    HEPA filter H-14 for a pure air. Pristine air.

    filtro-cruma-hepa

    Absolute H14 HEPA Filter with a flow equalizer and an efficiency rate of over 99.995% for particles measuring 0.3 microns. Standards MIL-F51068C and BS 3298. With an electronic chip to provide both the operators and the samples with the greatest possible degree of safety.